1.1 Introduction
The sea water desalination equipment is designed by international advanced reverse osmosis technology and optimized system.
According to the water quality report information provided by the customer, the raw water is sea water, and the product water quality is <500ppm.
According to the water source part of the data, the following process design is made.
1.2 Principles of Compilation
1) Strictly implement the national environmental protection policy; in line with relevant national laws & regulations,policies, norms and standards;give full play to the social,environmental and economic benefits of project construction.
2) We choose the water treatment process according to local conditions,and we strive to the mature & reliable, efficient & energy saving process to ensure the effect of water treatment and the purpose of using advanced, economically reasonable technology.
3) In this proposal, we choose specialized equipment that adopted advanced, reliable, efficient, simple operation & maintenance method, which offer the room for selection and comparison.
4) We implement energy conservation policy to reduce the cost of operation and management.
5) Modernized & automatic controlling technology is adopted to achieve automatic management, and reduce labor intensity and management costs.
6) The proposal reasonably determines the scale of the project to make the limited water resource maximize its benefits.
7) The water treatment system is stable and reliable, cause double circuit power supply, enough handling facilities and operation equipment are adopted.
8) The proposal actively and securely uses new technology,advanced equipment, material.
1.3 Base Parameter
|
Raw Water Quality (seawater)
|
|
TDS
|
≦35000PPM
|
|
Inlet Temperature
|
5~45℃
|
|
Product Water Quality (City tap water standard)
|
|
TDS
|
≦500mg/L
|
|
Base parameter
|
|
Type
|
Sea water desalination
|
Unit
|
|
Inlet Flow
|
23.2
|
m3/h
|
|
Product Flow
|
10.42
|
m3/h
|
|
Desalination Rate
|
≧99.5
|
%
|
|
RO Recovery Rate
|
45
|
%
|
|
Operating Pressure
|
3.5-5.5
|
Mpa
|
|
Protection Levels
|
IP54
|
|
Voltage
|
380V / 50Hz /3 phase
|
|
Rated Power
|
50.5KW
|
|
Environment Temperature
|
0~45℃
|
|
Air Humidity
|
20~90%
|
1.4 Product Specification
|
250T/d RO SEA WATER DESALINATION EQUIPMENT
|
|
Model
|
WY-SW-250
|
|
Water Yield
|
250m3/d
|
|
Configurations
|
Japan Toray membrane, CW pump, Schneider
|
|
Application
|
City tap water/ Fresh water
|
|
Dimension
|
40 HQ container
|

3. System Design Specification
3.1System design implementation standard
3.1.1 Classification, technical requirements, test methods, inspection rules, marking, packaging, transportation and storage Execution: CB/T 3753-1995.
3.1.2 National standard for city tap water: GB5749-2022.
3.1.3 Ship noise limit and measurement method standard: GJB 763.5-1989.
3.1.4 Specification for construction and acceptance of low-voltage electrical installations for electrical installations: GB50254-9.
3.1.5 Low-voltage distribution equipment and line design specifications: GB50054-2011
3.1.6 Chemical equipment, pipeline anti-corrosion design conditions: HG/T 20679-2014.
3.1.7 Asbestos rubber gasket for pipeline: JB/T87-94.
3.1.8 Pipe flange standard: JB/T81-94.
3.1.9 Pipe flange technical conditions: JB/T74-94.
3.1.10 Lining plastic (PP, PE, PVC) steel pipe and fittings: HG20538-92.
3.1.11 Rubber-lined steel pipe and fittings: HG21501.
3.1.12 The manufacturing process and materials of imported equipment shall comply with the standards or equivalent standards involved in the industrial regulations of the American Society of Mechanical Engineers (ASME) and the American Society for Testing and Materials (ASTM).
3.2 Acceptance standard
National Sanitary Standard for drinking Water "GB5749-2022".
4. Electrical Control Instructions
4.1 Electrical Design Basis
Electrical professional design standards: "Industrial and Civil Power Distribution Design Manual."
Low-voltage distribution cabinets, power control box related standards:
GB7251-87 "low-voltage switchgear and control equipment."
JB/T9661 "Low-voltage withdrawable switchgear".
IEC60439-1 "Low-voltage switchgear and control equipment".
Control box protection level: GB4942.2-1985 "low-voltage electrical enclosure protection level".
Safety distance between electrical appliances:
GBJ54-83 "Design Specification for Low Voltage Distribution Devices and Circuits".
4.2 Electrical System Description
System voltage: 380V / three phase / 50HZ (can be changed according to customer’s needs).
The system air switch, contactor and thermal relay are evenly distributed by Schneider International.
The installation of power distribution cabinets, control cabinets, air switches and disconnectors are safe and reliable.
Set the ground wire according to the standard.
The system can effectively remove inorganic salts, heavy metal ions, organic matter, bacteria and other harmful components in water.
The system has installed new body case with all pipes made of resistant material, so that the whole system can use a long time.
RO system has adopted advanced RO system components and high-quality membranes elements, and has designed according to the equipment’s output combining with unique efficient technology so that the system can save much energy.
More advanced devices has been installed in this system, such as flow and pressure control meters、atmospheric valve and blow down piping, which make sure the whole system work stably , safely and conveniently.